소개
A method to recover atmospheric temperature profiles using a ground-based Fourier Transform Infrared spectrometer was investigated. The method used a difference form of the radiative transfer equation, a Bomem MR series Fourier Transform Infrared Spectrometer to collect atmospheric radiance values, and the Phillips Laboratory Expertassisted User Software (PLEXUS) atmospheric radiance model, to recover an atmospheric temperature profile.